In 1998, the central venous catheter (CVC) developed and produced by SCW Medicath Ltd. was successfully listed by National Medical Products Administration, China (NMPA) and used by major hospitals. SCW Medicath Ltd. is one of the first manufacturers to obtain product registration certificate in China. After more than 20 years of research and development and continuous improvement, the central venous catheter produced by SCW Medicath Ltd. has a considerable market in China, and the products are also exported to foreign countries. The tube body includes the image display under X-ray of the tube body, the surface treatment, the design and configuration of the tip and guide wire are all specially designed which can meet different needs of clinical needs. There are catheters of various lengths or specifications with single cavity, double cavity, three cavity and four cavity for clinical selection.
In general, the role of central venous catheter can be summarized into two aspects:
1. As a venous pressure measuring device: it is used in conjunction with the blood pressure sensor to measure the central venous pressure. See the figure below:
Central venous pressure is the pressure at the place where the superior and inferior vena cava enter the right atrium. It is measured through the superior and inferior vena cava or the built-in tube in the right atrium. It reflects the right atrial pressure and is one of the main indicators of hemodynamics in clinical observation. It is affected by three factors: cardiac function, circulating blood volume and vascular tension. Central venous pressure can be used as an index of liquid infusion speed and liquid infusion volume in clinic. It needs to be used in combination with blood pressure sensor. The latter is also the characteristic product of SCW Medicath Ltd., which will be introduced separately.
2. As a pathway of infusion for liquids, nutrients, medication et al. provides convenience for various clinical applications:
SCW Medicath Ltd. Produced CVC is for one-time use, and the longest retention time within the body for a single use shall not exceed 30 days. For long-term use, Peripheral central venous catheter (PICC, up to 1 year) and fully implantable intravenous infusion device (port, can be used for many years) can be considered.
SCW MEDICATH LTD, established in 1996 and headquartered in Shenzhen, is the first factory to develop and manufacture Central Venous Catheters, Blood pressure Transducer and many other products in China. As a professional medical manufacturer, SCW has been specialized in the field of Intervention, Anesthesiology & Critical Care, Obstetrics & Gynecology, Urology, Medical Imaging, Orthopedics and other high-value medical consumables. At present, SCW has more than 60 domestic registered products, and more than 30 CE certified products. SCW is certified by ISO13485 Quality System Certificate, and CE Certificate. SCW Products are sold across China, and exported to more than 80 countries and regions. For more information, please do not hesitate to contact us.